Our range of Clean Air Equipment, which includes Horizontal Flow Model, Bio Safety Cabinets, Vertical Flow Model. These equipment not only create over pressure inside the department to avoid dust ingress and also reduces down the temperature for comfortable working in the department.
Product Details:
Minimum Order Quantity | 1 Unit |
Usage/Application | Laboratory |
Air Flow | 70-80% |
Model Name/Number | MFI BSC |
Size | 2x2; 3x2; 4x2; 6x2 |
Color | White and Blue |
Features | Manual as well as Digital Models available |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Unit |
Brand | Microfilt |
Usage/Application | Hospital |
Material | Mild Steel and Stainless Steel |
Air Flow | 30% |
Size | 2' x 2' ; 3' x 2' ; 4' x 2' and 6' x 2' |
Height | 83.2" |
Color | White and Blue |
Features | Manual as well as Digital |
|
|||||
There are four types of Class II cabinets: Class II Type A1 (formerly designated Type A): It exhausts approximately 30% air back into the laboratory and re circulates the remainder. May have positive pressure contaminated ducts and plenums that are not surrounded by negative pressure plenums. Class II Type A2 (formerly designated Type B3): It exhausts approximately 30% air through a HEPA filter back into the laboratory or to the environment through an external exhaust duct. It has all biologically contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B1: It exhausts 70% air through a dedicated duct exhausted to the atmosphere after passing through a HEPA filter and re circulates the remainder. It has all contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B2: (sometimes referred to as "total exhaust"): It exhaust 100% air through an exhaust duct after passing through a HEPA filter and contaminated positive pressure plenums must be surrounded by a vacuum. Class III: The Class III cabinet is a totally enclosed ventilated cabinet of airtight construction. Operations within the Class III cabinet are through attached rubber gloves. When in use, the Class III cabinet maintains negative air pressure. Supply air is drawn into the cabinet through HEPA filter. The cabinet exhaust air is filtered by two HEPA filters installed in series, before it is discharged outside the facility. The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facilities ventilation system. |
|||||
Additional Information:
Product Details:
Minimum Order Quantity | 100 Unit |
Brand | Manufacturing |
Usage/Application | Safety cabinets |
Material | SS |
Main Filter | Aluminum Framed |
Exhaust Filter | Aluminum Framed |
Filter Face | 60 DB |
Product Details:
Minimum Order Quantity | 1 Unit |
Usage/Application | Laboratory |
Type | Horizontal |
Air Flow | 70% |
Model Name/Number | MFI H |
Size | 2' x 2' ; 3' x 2' ; 4' x 2' and 6' x 2' |
Lighting Type | UV |
Horizontal Laminar Air Flow Working & Features of Horizontal Laminar Flow Unit The Horizontal Laminar airflow provides product proteciton within the work area, which is confined by removable clear glass panels and polycarbonate shutter.
|
Additional Information:
Product Details:
Type | Horizontal |
Usage/Application | Laboratory |
Material | SS |
Surface Finish | Powder Coated |
Noise Level | Less than 65 DB |
Finish | Laminated |
Air Flow | 90 FPM (0.45 m/s) |
Pre Filter | Washable type |
Product Details:
Type | Vertical |
Usage/Application | Laboratory |
Material | SS |
Surface Finish | Polished |
Filters | Aluminum framed |
Pre Filter | Washable |
Air Flow | 90 FPM |
Noise Level | Less than 65 DB |