Heat Exchanger Lab Equipment

Pioneers in the industry, we offer condensation in drop & film forms, heat transfer agitated vessel, centrifugal blower test rig, critical radius of insulating material, plate type heat exchanger lab equipment and unsteady state of heat transfer apparatus from India.

Condensation In Drop & Film Forms

Request Callback

Get Latest Price

Product Brochure
Steam Generator1.5 kW capacity water heater
Rotameter25 - 250 LPH
Pressure Gauges0 to 2.1kg/sq
Condensers19mm
Body TypeMetal
The apparatus consists of a transparent glass cylinder at the top of which two condensers hang and steam is admitted at the bottom. One of the condensers is provided with chrome-plated surface for dropwise condensation and other with natural surface finish to promote filmwise condensation. Water is circulated through the condensers from common inlet. The transparent glass cylinder allows visualisation of condensation process.

Heat Transfer Agitated Vessel

Request Callback

Get Latest Price

MaterialSS
Power0.75 kW - 45 kW
Voltage220V
StandTable Support
DisplayDigital
SourceElectric Power Supply

Minimum order quantity: 1 Number

The addition and removal of heat is done by passing steam in jacket fitted to the outside of the vessel or passing cold. Water in helical coil inside the vessel. For effective heat transfer and even distribution of heat, the liquid inside is continuously agitated.

Centrifugal Blower Test Rig

Request Callback

Get Latest Price

Voltage380V
Speed2500 Rpm
MountingFree Standing
MaterailSS
Moter Power1 Hp
We are the leading Manufacture supplier exporter of Centrifugal Blower Test Rig and this product made by our expert with Good quality.

Critical Radius Of Insulating Material

Request Callback

Get Latest Price

Product Brochure
MaterialSS
Diameter80mm
Weight25-100 Kilograms (kg)
Voltage240V
Equipment MaterialsMetal

Minimum order quantity: 1 Number

The unit provides find out Critical Radius of Insulating Material, ratio of thermal conductivity and outside heat transfer co-efficient. The unit consists of four G. I. pipes provided with plaster of Paris insulation on out side surface and heater inside, having separate input control. Input to heaters is measured by common voltmeter& ammeter.

Plate Type Heat Exchanger Lab Equipment

Request Callback

Get Latest Price

Product Brochure
MaterialSS
Country of OriginMade in India
Voltage200V
Ammeter0-2Amp
Inner Sphere Diameter100mm
SuportTable Stand

Minimum order quantity: 1 Number

We are the leading Manufacture supplier exporter of Plate Type Heat Exchanger and this product made by our expert with Good quality .

Unsteady State Of Heat Transfer Apparatus

Request Callback

Get Latest Price

Product Brochure
MaterialSS
Outer Sphere Diameter200mm
Voltage200V
Ammeter0-2Amp
FrameMetal Frame

Minimum order quantity: 1 Number

We offer a world class Unsteady State Of Heat Transfer Apparatus to our clients. These Heat Exchangers are manufactured using latest technology and machines. These products are fabricated with top grade material and components. Our range of heat exchangers is extremely efficient and durable. They exchangers are highly known for their long life, smooth operations and good service. This product is extremely used in various applications like space heating, air conditioning, natural gas processing, sewage treatment, and petroleum refineries. We also customize these products as per our clients given specifications. This product is available in industry leading prices for our clients.

Heat Transfer Through Composite Wall

Request Callback

Get Latest Price

Product Brochure
MaterialSS
Country of OriginMade in India
Power220V
Approx Weight70 kg
Display TypeDigital Meter
SupportTable Stand

Minimum order quantity: 1 Number

Composite materials are widely used for purposes associated with transfer of heat. Therefore it is important to determine the rate of heat transfer through different layers of composite wall and develop expressions that model the heat transfer in composites.

Lagged Pipe Apparatus

Request Callback

Get Latest Price

Usage/ApplicationChemical Laboratory
MaterialSS
Electricity Supply1Phase, 220 V AC
Inner Sphere Diameter100mm
Ammeter2 Amp
The setup is designed and fabricated to study lagging phenomenon in case of pipes. It consists of three concentric pipes of small thickness as compared to diameter and are arranged concentrically, and closed with the help of two discs. Two different insulating materials fill the annuli between the cylinders compactly. Temperature Sensors are fitted to measure the temperature of pipe walls for radial outward heat flow measurement. Inside the inner pipe, a Nichrome wire heater is placed axially. Heat input to the heater is given through a variac and measured by Digital Voltmeter and Digital Ammeter. By varying the heat-input rates, wide range of experiments can be performed

Experiments:

  • To estimate the actual rate of heat transfer through the composite cylinders from the measured interface temperature of the known value of thermal conductivity of the two insulating materials.
  • To determine the effective thermal conductivity of the composite cylinders
  • To determine the theoretical temperature profile within the composite cylinders

Composite Walls Apparatus

Request Callback

Get Latest Price

Product Brochure
MaterialMild Steel
Heat Transfer TypeCompact
Flow TypeHybrid Flow
Inner Sphere Diameter100mm
Voltage200V
Ammeter0-2Amp
Digital Temperature0-300 dig C
We are engaged in offering high quality Composite Walls Apparatus to the esteemed customers. These apparatuses are manufactured using genuine raw material, under the able guidance of our team of experts. Moreover, we make sure to timely deliver the ordered products at the customers' end, via our wide distribution network.

Features:

  • High performance
  • Superior design
  • Low power consumption
  • User-friendly functions
  • Used high quality raw material
  • Economic prices

Pin Fin Apparatus

Request Callback

Get Latest Price

Product Brochure
MaterialSS
Voltage200V
Digital Temperature0-300 dig C
Inner Sphere Diameter60mm
SupportTable Stand

Minimum order quantity: 1 Number

The setup is designed to study the heat transfer in a Pin Fin Apparatus. It consists of pin type fin fitted in duct. A fan is provided on one side of duct to conduct experiments under forced draft conditions. Airflow rates can be varied with the help of damper provided in the duct. A heater heats one end of fin and heat flows to another end. Heat input to the heater is given through Variac. Digital Temperature Indicator measures temperature distribution along the fin.


Experiments:

  • To study temperature distribution along the length of fin in both Free & forced convection
  • Comparison of theoretical temperature distribution with experimentally obtained distribution

Forced Convection Apparatus

Request Callback

Get Latest Price

Product Brochure
Country of OriginMade in India
UseAuto Testing Machine
Temp Accuracy+-1 dig C
MaterialSS
PowerElectronic
Bench Area1m. x 0.75 m

Minimum order quantity: 1 Number

The unit consists of a circular pipe, loosing heat by forced convection to air, being forced through it. Constant heat flux is added to pipe by an electrical heater, provided with input control.

Specific Heat Of Air Apparatus

Request Callback

Get Latest Price

Product Brochure
MaterialSS
Country of OriginMade in India
UseAuto Testing Machine
PowerElectronic
Temperature Range+10dig C ~ +200

Minimum order quantity: 1 Number

The Specific Heat of Air Apparatus has a Constant speed fan with variable flow control valve The heater is located at the center of the test section. The forced air flowing through the pipe causes the heat transfer due to convection process. Specific Heat is evaluated by taking the heat balance between heat supplied by heater and heat gained by air.

Critical Heat Flux Apparatus

Request Callback

Get Latest Price

Product Brochure
Heat Transfer TypeCompact
MaterialSS
Voltage200V
Digital Temperature0-300 dig C
Ammeter0-2Amp
The apparatus consists of a nichrome wire immersed in water. The nichrome wire is heated by passing current through it.

Natural Convection Apparatus

Request Callback

Get Latest Price

Dimension200mm x 200mm x 800 mm(LxWxH)
Voltage220V
MaterialSS
Voltmeter0 - 300 V
Ammeter0 - 5 A

Minimum order quantity: 1 Number

The unit consists of a vertical brass pipe heated by a cartridge heater inside. The pipe looses heat to atmosphere by natural convection. It is fitted in an enclosure to provide undisturbed natural convection currents. Thermocouples are attached on the pipe to measure local temperatures. Heater input is measured on voltmeter and ammeter. Thus students can determine overall heat transfer coefficient and local heat transfer coefficients in natural convection at various heat transfer rates.

Emissivity Measurement Apparatus

Request Callback

Get Latest Price

MaterialSS
Diameter160mm
UseUniversal Testing Machine
PowerElectronic
Voltage230V
Ampere15A

Minimum order quantity: 1 Number

he apparatus consists of a test plate and a comparator. A black plate is used as a comparator for test plate. When all the physical, dimensions and the temperatures are equal, heat losses from both plates will also be the same, except radiation losses.

Hence the input difference will be due to difference in emissive. Both the plates are kept in a panel enclose with perplex front and are given inputs through separate dimmerstats so that temperatures of both can be kept equal. Thus emissivity can determine over a wide range of temperatures.

Heat Pipe Demonstrator

Request Callback

Get Latest Price

MaterialSS
Digital Ammeter0-2 Amp
Electricity Supply1 Phase, 220 V AC
Diameter32mm
Heating Power30W

Minimum order quantity: 1 Number

Having capabilities to determine the axial heat flux in a heat pipe using water as working fluid with that in a solid copper rod with temperatures.

Thermal Conductivity Of Liquid

Request Callback

Get Latest Price

MaterialMild Steel
Accuracy+-3%
PowerElectronic
UseThermal Analysis Instruments
Test Range0.005--300W/(m*K)
Thermal conductivity of liquid is an important engineering property. The apparatus uses guarded hot plate method for determining the thermal conductivity. It consists of a hot plate i.e. an electrical heater sandwiched between aluminum plates. The heat loss from hot plate is prevented by using two guard heaters and heat of hot plate is made to flow through specimen. Cold plate on opposite face of liquid removes heat from liquid by circulation of water. Input to heaters can be varied and measured. The temperatures are measured by a digital temperature indicator.

Heat Pipe Demonstrator

Request Callback

Get Latest Price

Product Brochure
MaterialSS
Electricity Supply1 Phase, 220 V AC
Digital Ammeter0-2 Amp
Diameter32mm
BodyMetal

Minimum order quantity: 1 Number

It is a super-conducting device and involves the transfer of heat by boiling and condensation of a fluid and hence transfer of heat takes place under nearly isothermal condition. In this apparatus the comparison of heat pipe with the copper pipe as good conductor of heat and with the stainless steel pipe as same material of construction is made. It consists of three identical cylindrical conductors In respect of geometry. One end of these is heated electrically while there are small capacity tanks acting as heat sinks at the other end. The unit consists of a heat pipe a copper pipe and a stainless steel pipe. Temperature sensors are embedded along the length to measure the temperature distribution and the heat transfer rate is noted in terms of the temperature rise in the heat sink tanks.

Tube Heat Exchanger

Request Callback

Get Latest Price

Product Brochure
Medium UsedWater
Heat Transfer TypeCondensers
Primary Exchanger MaterialSteel
Flow TypeParallel Flow
MaterialSS
Power0.5~100 kW
TypeTube Typle
Inner MaterialCopper

Minimum order quantity: 1 Number

Tube Heat Exchanger are widely used in various industries. Finned tube Heat Exchanger is a Tube-in-tube type heat exchanger. The inner tube is of cooper tube with fins on the outside surface. Hot water flows through inner tube and cold fluid flows over the inner tube in outer tube. The flow rate of hot & cold fluid is measured with the help of measuring cylinder &stopwatch. Inlet and outlet temperatures of fluids are measured with the help of digital temperature indicators. A magnetic drive pump is used to circulate the hot water from a re-cycled type water tank, which is fitted with heaters and Digital Temperature Controller.

Thermal Conductivity Of Metal Rod

Request Callback

Get Latest Price

Product Brochure
MaterialSS
PowerElectronic
Metal Bar25mm
UseThermal Conductivity Tester
Capacity0-230v, 2A

Minimum order quantity: 1 Number

The test section of bar is properly insulated & thermocouples are attached to observe the temperature gradient along the length of bar. Heat conducted through the section of bar is measured by heat collection in water-cooled heat sink.

Thermal Conductivity Of Circular Insulating Slabs

Request Callback

Get Latest Price

Product Brochure
Display TypeAnalog
PowerSIngle Phase Supply
MaterialSS
Voltage220V
Heater Plate Diameter100mm
TemperatureUpto 130dig C
The apparatus consists of a slab assembly. The main heater and a radial guard heater are sandwiched between plates. The specimen in the form of slabs of equal thickness are placed on either sides of heaters and cooling plates through which water is circulated are on the other sides of specimen. Radial guard heaters ensures all heat of main heater passes axially through the specimens, which is collected by cooling plates.
X

Contact Us

Inder Dara (CEO)
Scientific Corporation
No. 112, 1st Floor, Ganesh Chambers, Mehadia Square
Dhantoli, Nagpur - 440012, Maharashtra, India

Get Directions
Send Email